= List of things to have all the time in 431 =
 
  
* Always at least one full bottle of autoclaved water
 
* Always at least one full spray flask of 75% alcohol
 
* Always one half full bottle of DMEM supplied with extras
 
* Yellow waste container no more than 3/4 filled
 
* Check that sticky mat sticks
 
* Empty Vacusafe when it is more than half full
 
* Once a week, refill sterile water in incubator. Need: 1-2 l.
 
* When the diluted PBS bottle is less than half full prepare another
 
* Check the list of things to buy (on the wall in the fore-room)
 
* Check the CO2 level in bottles. Reorder bottle if necessary.
 
* Always at least 20 sterile pasteur pipettes in hood, if not: autoclave new
 
 
 
= List of procedures =
 
 
== Autoclaved water ==
 
 
Must be done 4-5 hours before use of water (for cooling down)
 
* Get 5l bottles of water from chemistry (check quality resistivity > 1MOhm)
 
* Fill 1l glass bottle with water
 
* put cap on, untighten cap
 
* put autoclave scotch on
 
* put in autoclave and follow procedure on autoclave
 
 
== Dulbeccos Modified Eagle Media, DMEM adding extras ==
 
 
* Inside sterile hood with sterile procedures
 
* Open new bottle of DMEM
 
* Add 50 ml FBS
 
* Add 5 ml Penicilin Streptomycin
 
 
== Vacusafe ==
 
* Add chlorine?
 
* Pour into yellow waste container ?
 
 
== Refilling water in incubator ==
 
* Have 1-2 l sterile water ready and spray top around lid
 
* Put on gloves and spray gloves
 
* Open incubator
 
* withdraw water pan half way
 
* pour water in to half full
 
 
== Preparing diluted PBS ==
 
* zdf
 
 
== Autoclaving pasteur pipettes ==
 
* stock in cupboard in 431
 
* put them in a 1l beaker
 
* ...
 

Latest revision as of 15:21, 17 November 2023