This is a page dedicated to Bioactuator's student group that was active in 2023.
 
 
 
# Set-up Test
 
 
 
Participants: Emilie Haugland Solheim, Silje Vik, Sander Iden
 
Created By: Emilie Haugland Solheim
 
Type: Lab, Passaging
 
Created: May 27, 2023 6:44 PM
 
Last Edited Time: May 27, 2023 7:38 PM
 
 
 
Agenda:
 
 
 
- Passaging
 
- Testing electrodes in the six-well plate with growth medium and shapes
 
 
 
Testing with a sinus-signal of 1 Hz frequency and an amplitude of 11.5 Vpp, 1st try:
 
 
 
- During testing, there was a layer of something (goop?) growing on the electrodes. Maybe caused by electrolysis (which we don’t want)?
 
- Time: about 1 min (short time)
 
- A picture (Bubbles_from_around_electrodes_after_stimulation.png) was taken of the ‘goop’ that grew on the eletrodes. This looked like bubbles, and might be a ‘mild’ electrolysis.
 
   
 
   
 
 
 
Testing with a sinus-signal of 1 Hz frequency and an amplitude of 11.5 Vpp, 2nd try:
 
 
 
- Did the same again, but filming it (with Sanders phone). Same result as the 1st try.
 
- Video:
 
 
 
Testing with a square-signal of 1 Hz frequency and an amplitude of 11.5 Vpp, 1st try:
 
 
 
- Short time again (~1 min)
 
- Same happened. Same result as 1st and 2nd try with the sinus-signal.
 
 
 
Comments:
 
 
 
- Wish: Get new electrodes of same material and thickness (that are fit for medical use/in Vitro)
 