Difference between revisions of "Oppsummering"

From mn.fysikk.laglivlab
Jump to: navigation, search
 
Line 16: Line 16:
 
* Photolitho troubles, check out [https://www.elveflow.com/microfluidic-reviews/soft-lithography-microfabrication/su-8-mold-lithography/ Elveflow guides]
 
* Photolitho troubles, check out [https://www.elveflow.com/microfluidic-reviews/soft-lithography-microfabrication/su-8-mold-lithography/ Elveflow guides]
 
** Systematically test different illumination doses on small patterns
 
** Systematically test different illumination doses on small patterns
** Clean isopropanol and PMGEA
 
 
** Clean wafers properly in acetone (or piranha) before plasma cleaning. Try corona plasma inside LAF bench in 219 to avoid exposure to dust before hot plate
 
** Clean wafers properly in acetone (or piranha) before plasma cleaning. Try corona plasma inside LAF bench in 219 to avoid exposure to dust before hot plate
 +
** Check timing of programmable hot plate and fix it.
 +
** Developing
 +
*** Clean isopropanol and PMGEA
 +
*** Different container for PGMEA? smaller volume and cleaning procedure?

Latest revision as of 12:10, 22 June 2021

  • LowT agarose seems to be a workable starting gel for cells in 3D
    • it's easy to prepare
    • it can be mixed with collagen to give cells adhesive contacts
  • filling parts of microfluidic circuits with gel
    • 25 um thick SU8 worked fine with current patterns (30 um Ø posts)
    • 25 um thick circuits became sufficiently hydrophobic after 3-4 days to keep flow within posts
    • after 10-20 mm distance into circuit the flow resistance made the gel spill through the posts and into neighbouring areas
    • => Plans/ideas
      • shorter distances
      • thicker channels, but this requires better photolitho or wider posts
      • blocking fluid
        • dissolve out unreticulated PDMS with pentane/hexane before oxidising. This will keep the PDMS hydrophilic for weeks
        • fill neighbouring channels with perfluorodecalin (this is non-polar and will have a large contact angle with hydrophilic PDMS), see https://doi.org/10.1021/ac0346712
        • fill with agar solution
        • displace perfluorodecalin with cell media
  • Photolitho troubles, check out Elveflow guides
    • Systematically test different illumination doses on small patterns
    • Clean wafers properly in acetone (or piranha) before plasma cleaning. Try corona plasma inside LAF bench in 219 to avoid exposure to dust before hot plate
    • Check timing of programmable hot plate and fix it.
    • Developing
      • Clean isopropanol and PMGEA
      • Different container for PGMEA? smaller volume and cleaning procedure?