10.02.23

From mn.fysikk.laglivlab
Jump to: navigation, search

Present: Lasse, Elizabeth, Lynn, Felix

Pre-notes:

- The goal is to demonstrate that our setup produces reproducable rotation spectra, so we hope that the results today are similar to those from the experiments at 28.10.22 and 07.02.23.

- Consider asking about a new nitrogen tank to use in cleaning the chip.

- 0.4 ml of water more than necessary added to solution by accident, may affect electrical conductivity in medium and results. The chip was also washed with distilled water because we're missing isopropanol.

Results (rotations per 10sec):

Each row for a clip is a different cell.

10kHz 100kHz 200kHz 500kHz 1MHz 5Mhz 10MHz 20MHz 30MHz 40MHz 50MHz
0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0

Notes:

- No turning point, spectra possibly affected by additional water.