Difference between revisions of "Diluted PBS"

From mn.fysikk.laglivlab
Jump to: navigation, search
(Created page with "== Preparing diluted PBS == '''Instruction:''' 1<sup>st</sup>: Transfer 50 ml PBS stock solution into the empty 500 ml borosilicate glass bottle (work inside the bio LAF ben...")
 
(Preparing diluted PBS)
 
(6 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
== Required Items: ==
 +
 +
* 25 mL Serological Pipette
 +
* 500 mL volume metric flask
 +
* 500 mL borosilicate glass bottle
 +
* PBS [https://www.sigmaaldrich.com/NO/en/product/sigma/p5493 (PHOSPHATE BUFFERED SALINE 10× concentrate - P5493 from sigma / Merck) ]
 +
* Type II water
 +
 
== Preparing diluted PBS ==
 
== Preparing diluted PBS ==
 
'''Instruction:'''  
 
'''Instruction:'''  
Line 6: Line 14:
 
2<sup>nd</sup>: Transfer 450 ml type II water into the same above 500 ml borosilicate glass bottle. (work outside the LAF bench, on the lab bench)
 
2<sup>nd</sup>: Transfer 450 ml type II water into the same above 500 ml borosilicate glass bottle. (work outside the LAF bench, on the lab bench)
  
3<sup>rd</sup>: Autoclave the diluted PBS solution before using.  
+
3<sup>rd</sup>: [[Autoclaving | Autoclave]] the diluted PBS solution before using.  
 
 
'''Required Items:'''
 
 
 
25 ml Serological Pipette, 500 mL volume metric flask, empty 500 ml borosilicate glass bottle 
 
  
Stock solution:  (PBS - PHOSPHATE BUFFERED SALINE 10× concentrate - P5493) from sigma / Merck, Type II water
 
  
 
'''Work Steps'''
 
'''Work Steps'''
Line 22: Line 25:
 
Step 3: Transfer 50 ml PBS stock solution into the empty 500 ml borosilicate glass bottle and close the cap, then take out the bottle from LAF.  
 
Step 3: Transfer 50 ml PBS stock solution into the empty 500 ml borosilicate glass bottle and close the cap, then take out the bottle from LAF.  
  
Step 4: transfer 450 ml type II water with 500 mL volume metric flask into the 500 ml borosilicate glass bottle. (Work outside the LAF fume hood – just on lab bench).
+
Step 4: Transfer 450 ml type II water with 500 mL volume metric flask into the 500 ml borosilicate glass bottle. (Work outside the LAF fume hood – just on lab bench).
  
Step 5: Autoclave the diluted PBS solution.
+
Step 5: [[Autoclaving | Autoclave]]  the diluted PBS solution.

Latest revision as of 11:48, 17 November 2023

Required Items:

Preparing diluted PBS

Instruction:

1st: Transfer 50 ml PBS stock solution into the empty 500 ml borosilicate glass bottle (work inside the bio LAF bench to avoid polluting the stock PBS solution)

2nd: Transfer 450 ml type II water into the same above 500 ml borosilicate glass bottle. (work outside the LAF bench, on the lab bench)

3rd: Autoclave the diluted PBS solution before using.


Work Steps

Step 1:  Use 75% antibac ethanol alcohol to spray the pack surface of 25 ml Serological Pipette, the surface of the 500 ml borosilicate glass bottle and the bottle of stock solution.

Step 2: right after spray each item and place them inside the bio LAF hood.

Step 3: Transfer 50 ml PBS stock solution into the empty 500 ml borosilicate glass bottle and close the cap, then take out the bottle from LAF.

Step 4: Transfer 450 ml type II water with 500 mL volume metric flask into the 500 ml borosilicate glass bottle. (Work outside the LAF fume hood – just on lab bench).

Step 5: Autoclave the diluted PBS solution.