[[File:The Technician Room.jpg|alt=The Control room in the Socio-Cognitive lab, MULTILING|thumb|800x800px|The Technician Room in the Sociocognitive lab, MULTILING]]
+
[[File:The Technician Room.jpg|alt=The Control room|thumb|600px|The Control room]]
 
[[Category:Rooms and equipment]]
 
[[Category:Rooms and equipment]]
  
== HOWTO ==
+
== General information ==  
  
All the basic information should also be available in the technician's room as laminated instruction cards:
+
The control room is the operation center of the audio-video system. From here, you can monitor and control what is going on in the three testing rooms (video studio, EEG room, Eye-tracker room). Each of the testing rooms has cameras and microphones installed. The video studio has four cameras (one camera positioned in each of four corners of the room), the eye-tracker and EEG room have 1 camera respectively. All cameras can be operated from the control room. All cameras will get the same audio mixed in their video files with minimal drifting between sound and video. If needed, audio can be recorded in isolation (no video) or separated from the video after collection by the lab engineer.
  
[https://wiki.uio.no/hf/multiling/images/2/28/Handbook_AV-system_Feb2020.pdf Quick start]
+
== Audio-video system ==
  
User manuals for the Equpiment is stored as pdf documents on the Pc in this room. A copy is also stored [[User manuals|here]] 
+
The lab has a state-of-the-art audio-video system, which allows making customized recordings. All video, audio, and camera control systems are found on the recording computer (BigPC).  
  
 +
Detailed instructions on how to use the audio-video system can be found in the [https://docs.google.com/document/d/1UzafrWeWiSbrdvvLpkdmehujAOpHh2a3/edit?usp=sharing&ouid=102458362354574824068&rtpof=true&sd=true handbook]. It is also available in printed form in the control room.
 +
Note that for data protection reasons, you are obligated to save and delete your recordings from the lab equipment after every lab visit.
  
 +
== Introduction and training ==
  
=== First time ===
+
If you would like to use the audio-video system for the first time, get in touch with the lab manager or lab engineer. You will then make an appointment for a one-on-one visit where you will get a tour of the lab, get familiarized with the lab’s routines and code of conduct, and learn how to use the audio-video system. After successful training, you will get permission to use the audio-video system independently.
  
The first time you use the room you should be guided by one of the technicians. Be sure you request a guided tour well in advance so your valuable time isn't impeded by waiting for a technician who isn't on duty. If this is your first time and you are alone, please contact one of the technicians now.
+
For specific questions about the audio-video system and technical difficulties first consult the [https://docs.google.com/document/d/1UzafrWeWiSbrdvvLpkdmehujAOpHh2a3/edit#heading=h.gjdgxs handbook], and if that does not solve it, get in touch with the lab manager or lab engineer.
 
 
Upon entering the room for the first time you will hear alot of noise. This will most probably come from the rack where all the gadgets are placed. The fan noise from the network switches is the most prominent. All signals from the cameras and microphones goes through those switches and that generates alot of heat. The noise is unfortunate, but it cannot be alleviated. When you get past the noise you notice three screens. The first two are monitors that can show the video from all the cameras, four in the main studio and one in each of the pink and green rooms. The central control is the Crestron TSW-760-B-S panel. With this unit you select cameras and microphones, start the the recording and later stop it to transfer the finished recordings to the PC.
 
 
 
 
 
=== Select sources  ===
 
 
 
In the ___ control panel, select the video and audio sources. Before you start the recording, be sure to position the cameras.
 
In the sub menu for the cameras. You can also store presets by holding the save preset button and press one of the preset-buttons.
 
It is however recommended to use the Panasonic AW-RP50 to set up the cameras. The controller offers a lot more control an ability to fine tune the camera positions compared to the jerky motions from the touch panel. You still have to use the touch panel to select witch cameras that are showed on the monitors. And to save and recall presets. The recordings is not dependent of camera selection on the monitors.
 
 
 
=== All the gory details ===
 
If you are a normal researcher it should not be necessary for you to read this section. But some people might find the nitty gritty interesting.  The rack is the heart of the operations room. All the cameras send their signals over ethernet to the rack and the audio is also sent there as an analog signals witch is then sent to the cameras for embeding in the videostreams the N6123 DVR records the feeds and saves the files with one file per video feed. This is the most stable way to be sure that the video and audio will stay in sync during recordings.
 
The audio is also retrievable via eternet via the Dante protocol. After it has been converted to digtal signal via the Tiseria DSP.
 
 
 
Or if needed or you find it interesting the user manuals is also to be stored [[User manuals|here]]
 
 
 
[[File:multiling-logo-260px.jpg|right]]
 
[[Category:Rooms and equipment]]
 
  
 
== Visiting address ==
 
== Visiting address ==
  
The eye-tracker is located in room 114 of the lab.
+
The control rooom is located in room 114 of the lab.
  
  

Latest revision as of 11:27, 10 October 2023

The Control room
The Control room

General information

The control room is the operation center of the audio-video system. From here, you can monitor and control what is going on in the three testing rooms (video studio, EEG room, Eye-tracker room). Each of the testing rooms has cameras and microphones installed. The video studio has four cameras (one camera positioned in each of four corners of the room), the eye-tracker and EEG room have 1 camera respectively. All cameras can be operated from the control room. All cameras will get the same audio mixed in their video files with minimal drifting between sound and video. If needed, audio can be recorded in isolation (no video) or separated from the video after collection by the lab engineer.

Audio-video system

The lab has a state-of-the-art audio-video system, which allows making customized recordings. All video, audio, and camera control systems are found on the recording computer (BigPC).

Detailed instructions on how to use the audio-video system can be found in the handbook. It is also available in printed form in the control room. Note that for data protection reasons, you are obligated to save and delete your recordings from the lab equipment after every lab visit.

Introduction and training

If you would like to use the audio-video system for the first time, get in touch with the lab manager or lab engineer. You will then make an appointment for a one-on-one visit where you will get a tour of the lab, get familiarized with the lab’s routines and code of conduct, and learn how to use the audio-video system. After successful training, you will get permission to use the audio-video system independently.

For specific questions about the audio-video system and technical difficulties first consult the handbook, and if that does not solve it, get in touch with the lab manager or lab engineer.

Visiting address

The control rooom is located in room 114 of the lab.


Socio-Cognitive Laboratory

Room 114

Henrik Wergelands hus

Niels Henrik Abels vei 36

0313 OSLO